XUV / Soft X-ray imaging in vacuum
Image Deep UV / VUV and soft X-Ray using a range of open-face MCP detectors.
CAD designed for each application
down to 8 ns
to enhance Quantum Efficiency
18, 25, 40 and 75 mm active diameter
of flange size and type, or unmounted
with phosphor screen providing 5 ns FWHM timing
as an alternative to a phosphor screen
Synchrotron Radiation
VUV Imaging
The table below outlines the Part Number format for our standard product range. To talk further about these products, or the custom design of an image intensifier for your application, then please Contact us.
is a 25mm diameter single MCP image intensifier, with a fused silica input window, S20 photocathode, and P43 phosphor, on a fibre optic output window
TYPE | # of MCPs | Size | Phosphor | Output |
VID | 1 | 10 | P43 | G (Glass) |
2 | 18 | P46 | IFO (Fibre Optic) | |
3 | 25 | P47 | ITA (Fibre Taper) | |
40 | (Others upon request) | RS (Resistive Sea Anode) | ||
75 |
Type (Colour) | Screen efficiency % (Optical Watts / Electrical Watt) | Peak | Photons / Electron @ 5 kV | Decay Characteristic | Decay Curve |
P11 (Blue) | 5.9 | 446 | 120 | Fast initial decay with long decay at low level. | |
P20 (Green) Fast | 12 | 540 | 320 | Fast initial decay with long decay at low level. | |
P24 (Blue) | 5.0 | 500 | 120 | 10 ms to 10% | |
P31 (Green) | – | 550 | – | 1 ms, good exponential | |
P43 (Green) | 8.7 | 548 | 240 | 1.2 ms/decade, true exponential | |
P46 (Green) | 1.8 | 530 | 55 | 300 ns | |
P47 (Blue) | 3 | 410 | 64 | 80 ns | |
FS | 4.2 | 513 668 768 | 96 | 12 us to 10 % | |
GOS | 0.7 | 420 | – | 50 ns to 10 % | 110 ns to 1 % |
Range Size | Detectors | ||||||||
Nominal OO/ID | VID-12 | VID-18 | VID-25 | VID-40 | VID-75 | VPM-6 | VPM-12 | VPM-25 | VPM-40 |
CF36 70mm/35mm | S | S | N | N | N | S | N | N | N |
CF63 114mm/63mm | O | S | S | N | N | O | S | N | N |
CF100 152mm/100mm | O | O | O | S | N | O | O | S | N |
CF150 203mm/150mm | O | O | O | O | S | O | O | O | S |
CF200 254mm/200mm | O | O | O | O | O | O | O | O | O |
CF250 304mm/250mm | O | O | O | O | O | O | O | O | O |
S – Standard Configuration | O – Optional Configuration | N- Not Available |
Spectral responses of available photocathodes. Note that the underlay on the cathode can affect the QE.
Transmission of input windows
Lorem ipsum dolor sit amet, consec tetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt.
Lorem ipsum dolor sit amet, consec tetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt.
Lorem ipsum dolor sit amet, consec tetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt.
Lorem ipsum dolor sit amet, consec tetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt.
26 Castleham Road
St Leonards on Sea
East Sussex, TN38 9NS
United Kingdom